  uncompromising performance for standard waveforms the agilent technologies 33120A function/arbitrary waveform generator uses direct digital-synthe- sis techniques to create a stable, accurate output signal for clean, low- distortion sine waves. it also gives you fast rise- and fall-time square wave, and linear ramp waveforms down to 100 hz. custom waveform generation use the 33120A to generate complex custom waveforms such as a heart- beat or the output of a mechanical transducer. with 12-bit resolution, and a sampling rate of 40 msa/s, the 33120A gives you the flexibility to create any waveform you need. it also lets you store up to four 16,000- deep waveforms in nonvolatile memory. easy-to-use functionality front-panel operation of the 33120A is straightforward and intuitive. you can access any of ten major func- tions with a single key press or two, then use a simple knob to adjust fre- quency, amplitude and offset. to save time, you can enter voltage val- ues directly in vp-p, vrms or dbm. internal am, fm, fsk and burst modulation make it easy to modulate waveforms without the need for a separate modulation source. linear and log sweeps are also built in, with sweep rates selectable from 1 ms to 500 s. gpib and rs-232 inter- faces are both standard, plus you get full programmability using scpi commands. optional phase-lock capability the option 001 phase lock/tcxo timebase gives you the ability to gen- erate synchronized phase-offset sig- nals. an external clock input/output lets you synchronize with up to three other 33120As or with an external 10-mhz clock. option 001 also gives you a tcxo timebase for increased frequency sta- bility. with accuracy of 4 ppm/yr, the tcxo timebase make a 33120A ideal for frequency calibrations and other demanding applications. with option 001, new commands let you perform phase changes on the fly, via the front panel or from a computer, allowing precise phase calibration and adjustment. link the agilent 33120A to your pc the included agilent intuilink soft- ware allows you to easily create, edit, and download complex waveforms using the intuilink arbitrary waveform editor. or you can capture a waveform using intuilink oscilloscope or dmm and send it to the 33120A for output. for programmers, activex components can be used to control the instrument using scpi commands. intuilink provides the tools to easily create, download, and manage wave- forms for your 33120A. to find out more about intuilink, visit www.agilent.com/find/intuilink . the 33120A can also be used in con- junction with the 34811a benchlink arb software. this windows?-based program lets you create and edit waveforms on your pc and download them to the 33120A. ? 15 mhz sine and square wave outputs ? sine, triangle, square, ramp, noise and more ? 12-bit, 40msa/s, 16,000-point deep arbitrary waveforms ? direct digital synthesis for excellent stability agilent 33120A function/arbitrary waveform generator data sheet
2 waveforms standard sine, square, triangle, ramp, noise, sin(x)/x, exponential rise exponential fall, cardiac, dc volts. arbitrary waveform length 8 to 16,000 points amplitude resolution 12 bits (including sign) sample rate 40 msa/s non-volatile memory four (4) 16,000 waveforms frequency characteristics sine 100 ?z - 15 mhz square 100 ?z - 15 mhz triangle 100 ?z - 100 khz ramp 100 ?z - 100 khz white noise 10 mhz bandwidth resolution 10 ?z or 10 digits accuracy 10 ppm in 90 days, 20 ppm in 1 year, 18? - 28? temp. coeff < 2 ppm/? aging < 10 ppm/yr sinewave spectral purity harmonic distortion dc to 20 khz -70 dbc 20 khz to 100 khz -60 dbc 100 khz to 1 mhz -45 dbc 1 mhz to 15 mhz -35 dbc spurious (non-harmonic) dc to 1 mhz < -65 dbc 1 mhz to 15 mhz < -65 dbc + 6 db/octave total harmonic distortion dc to 20 khz <0.04% phase noise <-55 dbc in a 30 khz band signal characteristics squarewave rise/fall time < 20 ns overshoot 4% asymmetry 1% + 5ns duty cycle 20% to 80% (to 5 mhz) 40% to 60% (to 15 mhz) triangle, ramp, arb rise/fall time 40 ns (typical) linearity <0.1% of peak output setting time <250 ns to 0.5% of final value jitter <25ns output characteristics amplitude (into 50 ? ) 50 mvpp - 10 vpp [1] accuracy (at 1 khz) 1% of specified output flatness (sinewave relative to 1 khz) < 100 khz 1% (0.1 db) 100 khz to 1 mhz 1.5% (0.15 db) 1 mz to 15 mhz 2% (0.2 db) ampl 3vrms 3.5% (0.3 db) ampl < 3vrms output impedance 50 ? (fixed) offset (into 50 ? ) [2] + 5 vpk ac + dc accuracy 2% of setting + 2 mv resolution 3 digits, amplitude and off- set units vpp, vrms, dbm isolation 42 vpk maximum to earth protection short circuit protected 15 vpk overdrive < 1 minute modulation am carrier -3db freq. 10 mhz (typical) modulation any internal waveform including arb frequency 10 mhz - 20 khz depth 0% - 120% source internal/external fm modulation any internal waveform including arb frequency 10 mhz - 10 khz deviation 10 mhz - 15 mhz source internal only fsk internal rate 10 mhz - 50 khz frequency range 10 mhz - 15 mhz source internal/external (1 mhz max.) burst carrier freq. 5 mhz max. count 1 to 50,000 cycles or infinite start phase -360 to +360 internal rate 10 mhz - 50 khz 1% gate source internal/external gate trigger single, external or internal rate sweep type linear or logarithmic direction up or down start f/stop f 10 mhz - 15 mhz speed 1 ms to 500 s 0.1% trigger single, external, or internal rear panel inputs ext. am modulation 5 vpk = 100% modulation 5k ? input resistance external trigger/ ttl low true fsk/burst gate system characteristics [3] configuration times [4] function change: [5] 80 ms frequency change: [5] 30 ms amplitude change: 30 ms offset change: 10 ms select user arb: 100 ms modulation parameter change: <350 ms arb download times over gpib arb length binary ascii integer ascii real [6] 16,000 points 8 sec 81 sec 100 sec 8,192 points 4 sec 42 sec 51 sec 4,096 points 2.5 sec 21 sec 26 sec 2,048 points 1.5 sec 11 sec 13 sec arb download times over rs-232 at 9600 baud: [7] arb length binary ascii integer ascii real [8] 16,000 points 35 sec 101 sec 134 sec 8,192 points 18 sec 52 sec 69 sec 4,096 points 10 sec 27 sec 35 sec 2,048 points 6 sec 14 sec 18 sec [1] 100 mvpp - 20 vpp into open circuit [2] offset 2x pk - pk amplitude [3] times are typical. may vary based on controller performance [4] time to change parameter and output the new signal. [5] modulation or sweep off [6] times for 5-digit and 12-digit numbers [7] for 4800 baud, multiply the download times by two; for 2400 baud, multiply the download times by four, etc. [8] time for 5-digit numbers; for 12-digit numbers, multiply the 5-digit numbers by two
3 option 001 phaselock/tcxo timebase timebase accuracy setability < 0.01 ppm stability 1 ppm 0 - 50 aging < 2ppm in first 30 days (continuous operation) 0.1 pm/month (after first 30 days) external reference input lock range 10 mhz 50 hz level -10 dbm to + 15 dbm +25 dbm or 10 vpp max input impedance 50 ? 2%, 42 vpk isola- tion to earth lock time < 2 seconds internal reference output frequency 10 mhz level > 1 vpp into 50 ? phase offset range + 360 to - 360 resolution 0.001 accuracy 25 ns trigger output level 5v zero-going pulse pulse width > 2? typical fanout capable of driving up to three 33120As ordering information agilent 33120A function/arb generator opt. 001 phase lock/tcxo timebase option general power supply 110v/120v/220v/240v 10% power line frequency 45 hz to 66 hz and 360 hz to 440 hz power consumption 50va peak (28 w average) operating environment 0? to 55? storage environment -40? to 70? state storage memory power off state automati- cally saved, 3 user configurable stored states interface ieee-488 and rs-232 standard language scpi - 1993, ieee-488.2 dimensions (w x h x d) bench top 254.4mm x 103.6mm x 374mm rack mount 212.6mm x 88.5mm x 348.3mm weight 4 kg (8.8 lbs) safety designed to ul-1244, csa 1010, en61010 emc tested to mil-461c, en55011, en50082-1 vibration and shock mil-t-28800, type iii, class 5 acoustic noise 30 dba warm-up time 1 hour warranty 1 year 254.4 mm 212.6 mm 374.0 mm 103.6 mm 88.5 mm 348.3 mm
ordering information 33120A function/arbitrary waveform generator accessories included operating manual, service manual, quick ref- erence guide, intuilink connectivity software, test data, and power cord options opt. 001 phase lock/tcxo timebase opt. 106 benchlink arb software (34811a) opt. 1cm rack mount kit (34190a)* opt. 910 extra manual set manual language options (please specify one) aba us english abd german abe spanish abf french abj japanese abz italian abo taiwan chinese ab1 korean accessories agilent 34161a accessory pouch agilent 34811a benchlink arb software *for racking two side-by-side, order both items below lock-link kit (p/n 5061-9694) flange kit (p/n 5063-9212) agilent technologies?test and measurement support, services, and assistance agilent technologies aims to maximize the value you receive, while minimizing your risk and prob- lems. we strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. our extensive sup- port resources and services can help you choose the right agilent products for your applications and apply them successfully. every instrument and system we sell has a global warranty. support is available for at least five years beyond the production life of the product. two concepts underlie agilents overall support policy: ?ur promise?and ?our advantage. our promise our promise means your agilent test and meas- urement equipment will meet its advertised performance and functionality. when you are choosing new equipment, we will help you with product information, including realistic perform- ance specifications and practical recommenda- tions from experienced test engineers. when you use agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. many self-help tools are available. your advantage your advantage means that agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other pro- fessional engineering services. experienced agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your agilent instruments and systems, and obtain dependable measure- ment accuracy for the life of those products. by internet, phone, or fax, get assistance with all your test & measurement needs phone or fax united states: (tel) 800 829 4444 canada: (tel) 877 894 4414 (fax) 905 282 6495 china: (tel) 800 810 0189 (fax) 800 820 2816 europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 latin america: (tel) (305) 269 7500 (fax) (305) 269 7599 taiwan : (tel) 0800 047 866 (fax) 0800 286 331 other asia pacific countries: (tel) (65) 6375 8100 (fax) (65) 6836 0252 email: tm_asia@agilent.com online assistance: ww.agilent.com/find/assist product specifications and descriptions in this docu- ment subject to change without notice. windows is a u.s. registered trademark of microsoft corporation. ?agilent technologies, inc. 2001, 2004 printed in usa, may 1, 2004 5968-0125en www.agilent.com/find/emailupdates get the latest information on the products and applications you select. agilent email updates